Leave Your Message

G.657.A2 Bending Insensitive Single-mode Optical Fiber

The bending insensitive single-mode optical fiber G.657.A2, is available in 200 μm & 242 μm diameters. Since dedicated high-performance acrylic composites are used for coating protection, the fiber still has outstanding bending loss characteristics while reducing the size. Small size optical fiber can save a lot of space occupancy of pipeline and increase the core capacity of cable, which is the best choice for pipeline network.

    Application Scenarios

    > High density metropolitan area network and narrow space access network
    > Blowing tiny cables
    > FTTx

    Performance Features

    > Specialized resin composite material and smaller bending loss properties
    > The  smaller  size  optical  fiber  is optional. Reduce the  cable  sectional  area  for more than 30% and the density of the cable is increased, which can effectively save pipeline resource

    Product Specification

    Parameter

    conditions

    Units

    value

    Optical

    Attenuation

    1310 nm

    dB/km

    ≤ 0.350

    1383 nm

    dB/km

    ≤ 0.350

    1550 nm

    dB/km

    ≤ 0.210

    1625 nm

    dB/km

    ≤ 0.230

    Attenuation vs. Wavelength

    1310 nm VS. 1285- 1330 nm

    dB/km

    ≤ 0.05

    1550 nm VS. 1525- 1575 nm

    dB/km

    ≤ 0.04

    Zero Dispersion Wavelength

    -

    nm

    1300 - 1324

    Zero Dispersion Slope

    ps/(nm2 ·km)

    0.073 - 0.092

    Dispersion

    1550nm

    ps/(nm ·km)

    13.3- 18.6

    1625nm

    ps/(nm ·km)

    17.2-23.7

    Polarization  Mode  Dispersion

    (PMD)

    -

    ps/√km

    ≤ 0.2

    Cut-off Wavelength λcc

    -

    nm

    ≤ 1260

    Mode Field Diameter (MFD)

    1310 nm

    μm

    8.6±0.4

    1550 nm

    μm

    9.6±0.5

    Attenuation Discontinuity

    1310 nm

    dB

    ≤ 0.03

    1550 nm

    dB

    ≤ 0.03

    Geometrical

    Cladding Diameter

    μm

    125±0.7

    Cladding Non-Circularity

    %

    ≤ 0.8

    Core/Cladding Concentricity Error

    μm

    ≤ 0.5

    Coating Diameter (Uncolored)

    μm

    242±7 (standard)

    μm

    200±10 (optional)

    Coating/Cladding Concentricity Error

    μm

    ≤ 12

    Curl

    m

    ≥ 4

    Environmental (1550nm, 1625nm)

    Temperature Cycling

    -60℃ to +85℃

    dB/km

    ≤ 0.05

    High Temperature & High

    Humidity

    85℃, 85% RH, 30days

    dB/km

    ≤ 0.05

    Water Immersion

    23℃, 30days

    dB/km

    ≤ 0.05

    High Temperature Aging

    85℃, 30days

    dB/km

    ≤ 0.05

    Mechanical

    Proof Stress

    -

    GPa

    0.69

    Coating Strip Force *

    Peak

    N

    1.3 - 8.9

    Average

    N

    1.0 - 5.0

    Tensile Strength

    Fk=50%

    GPa

    ≥ 4.00

    Fk= 15%

    GPa

    ≥ 3.20

    Dynamic Fatigue (Nd)

    -

    -

    ≥ 20

    Macrobending Loss

    Ø30 mm×10 t

    1550 nm

    dB

    ≤ 0.03

    1625 nm

    dB

    ≤ 0. 1

    Ø20 mm×1 t

    1550 nm

    dB

    ≤ 0. 1

    1625 nm

    dB

    ≤ 0.2

    Ø15 mm×1 t

    1550 nm

    dB

    ≤ 0.4

    1625 nm

    dB

    ≤ 0.8

    * The peak peel force of the coating is 0.6-8.9N, and the average value is 0.6-5.0N when the coating diameter is 200±10.